You are here: Register Set > Analog Input Frame Maximum (Index=44, RB='1')
STX104 Reference Manual
ContentsIndexHome
PreviousUpNext
Analog Input Frame Maximum (Index=44, RB='1')

Analog Input Frame Maximum Register. Maximum Frame range is 0 to 2,147,483,648 Frames.

Register Layout

 

Index=0x2C, Byte 0. Index=0x2C, Word 0. RB='1'.  

D7 
D6 
D5 
D4 
D3 
D2 
D1 
D0 
AIFM7 
AIFM6 
AIFM5 
AIFM4 
AIFM3 
AIFM2 
AIFM1 
AIFM0 

 

Index=0x2D, Byte 1. Index=0x2C, Word 0. RB='1'.

D15 
D14 
D13 
D12 
D11 
D10 
D9 
D8 
AIFM15 
AIFM14 
AIFM13 
AIFM12 
AIFM11 
AIFM10 
AIFM9 
AIFM8 

 

Index=0x2E, Byte 2. Index=0x2E, Word 1. RB='1'.

D23 
D22 
D21 
D20 
D19 
D18 
D17 
D16 
AIFM23 
AIFM22 
AIFM21 
AIFM20 
AIFM19 
AIFM18 
AIFM17 
AIFM16 

 

Index=0x2F, Byte 3. Index=0x2E, Word 1. RB='1'.

D31 
D30 
D29 
D28 
D27 
D26 
D25 
D24 
AIFM31 
AIFM30 
AIFM29 
AIFM28 
AIFM27 
AIFM26 
AIFM25 
AIFM24 
Bit Definitions
NAME 
DIRECTION 
DEFAULT 
DESCRIPTION 
AIFM[31:0] 
rw 
0x00000000 
Analog Input Frame Maximum 

When the value of the Analog Input Frame Counter reaches the value in the Analog Input Frame Maximum Register, and output is generated which can be used to generate such things as interrupts, trigger-stops, etc. 

 

Frame Count Maximum Range: 1 <= AIFM <= 2147483648. 

 

Range: 0 to 2147483648 Frames. 

Resolution: 1 Frame

 

Counting every ADC-sample at 5 microsecond sample rate, the maximum can be set to just under 3 hours. 

Counting every ADC-Burst at 50uSec/ADC-Burst (20KHz), the maximum can be set to just under 29 hours.

Copyright © 1997-2008 by Apex Embedded Systems. All rights reserved. Updated on Wednesday, April 02, 2008.